+86 13928884373

Video Contact Us

All Categories

TJ Burner

Home >  Products >  Industrial Burner >  TJ Burner

Hot Selling TJ0200 Gas Burner Nozzle Industrial Premixed Burner Alloy Tube Nozzle

75kw-2000kw Furnace burner nozzle

-High performance velocity burners
-The highest operating velocity of any burner available
-Integrated gas and air orifices simplify burner piping, set-up and
-adjustmentAir and gas inlets are independently adjustable in 90° increments tosuit a variety of piping --alternativesInstallation, operation, and maintenance are simplified and less costlyAll models are available for use -with preheated combustion air

Description

.1

Blank_TJ0040 (1).jpgBlank_TJ0040 (2).jpgBlank_TJ0150 (1).jpgBlank_TJ0150 (2).jpgBlank_TJ0200 (1).jpg

 

 

Parameter
Burner Velocity
Model TJ0150
Model TJ0200
Max input, Btu/hr (KW)
Medium / High velocity
1,500,000(400) 2,000,000(586)
Min input, Ratio regulated Btu/hr (KW)
Medium / High velocity 150,000(44) 200,000(59)
Min input, Fixed air Btu/hr (KW)
Medium / High velocity 30,000(9) 40,000(12)

Main Gas Inlet Pressure, "w.c. (mbar)

Fuel pressure at gas inlet

High velocity Natural gas 14.5(36.0) 9.3(23.0)
Propane
15.0(38.0) 12.7(32.0)
Butane
15.5(39.0) 13.4(34.0)
Medium velocity Natural gas 7.0(17.5) 7.1(18.0)
Propane 6.0(15.0) 8.5(21.0)
Butane 6.5(16.0) 6.9(17.0)

Air Inlet Pressure, "w.c. (mbar)

15% excess air at maximum input

High velocity Natural gas 17.5(44.0) 12.3(31.0)
Propane 19.5(49.0) 14.1(35.0)
Butane 19.5(49.0) 14.1(35.0)
Medium velocity Natural gas 9.5(24.0) 10.0(25.0)
Propane 10.0(25.0) 11.0(28.0)
Butane 10.5(26.0) 11.0(28.0)
High Fire Visible Flame Length, inches (mm)
Measured from the outlet end of the combustor
High velocity Natural gas 38(965) 27(685)
Propane 42(1065) 30(760)
Butane 43(1090) 30(760)
Medium velocity Natural gas 43(1090) 36(915)
Propane 42(1065) 32(810)
Butane 44(1120) 32(810)
Approximate Flame Velocity, ft/s (m/s)
Approximately 15% excess air at maximum input
High velocity 500(152.4) 500(152.4)
Medium velocity 250(76.2) 250(76.2)
Flame Detection UV scanners only (Can be used with all combustors)
Fuel

Natural gas, propane, butane

For any other mixed gas, contact our company.

 
• All information is based on laboratory testing in neutral (0 "w.c., 0 mbar) pressure chamber. Different chamber
conditions may affect the data.
• All information is based on standard combustor design. Changes in combustor will alter performance and pressures.
• All inputs are calculated according to the high calorific value of the fuel.
• Our company reserves the right to change the construction and/or configuration of our products at any time without
being obliged to adjust earlier supplies accordingly.
• Plumbing of air and gas will affect accuracy of orifice readings. All information is based on generally acceptable air
and gas piping practices.